products:hardware
provided in the Blade and Spinner Hardware Kithttps://www.bergey.com/wp-content/uploads/excel-10-self-supporting-lattice-tower-installation-manual-2.pdf
26110000 Batteries and generators and kinetic power transmission
extraction:When filing for the tax credit on your Bergey Excel 15 wind turbine, the IRS may request a “Manufacturer’s Certification Statement”https://www.bergey.com/incentives/
Material: carbon-fiber (The rotor system consists of three high-technology carbon-fiber PowerFlex® blades.); AWEA RATED POWER (at 11 m/s or 25 mph) 15.6 kW kW (AWEA RATED POWER (at 11 m/s or 25 mph) 15.6 kW); AWEA ANNUAL ENERGY 29,800 kWh kWh (AWEA ANNUAL ENERGY (at 5 m/s average 29,800 kWh); CUT-OUT WIND SPEED none (CUT-OUT WIND SPEED none); MAXIMUM POWER 22.6 kW kW (MAXIMUM POWER 22.6 kW); ROTOR SPEED 0-150 RPM RPM (ROTOR SPEED 0-150 RPM); TYPE 3-Blade Upwind, Horizontal-Axis (TYPE 3-Blade Upwind, Horizontal-Axis); OVERSPEED PROTECTION Blade stall (OVERSPEED PROTECTION Blade stall); OUTPUT FORM 240VAC, 1-Phase, 60Hz (OUTPUT FORM 240VAC, 1-Phase, 60Hz); GENERATOR Permanent Magnet Alternator (GENERATOR Permanent Magnet Alternator); Turbine Weight 1350 lb (612 kg) lb (Turbine Weight: 1350 lb (612 kg)); Turbine Thrust Load 2500 Ib (11.1 kN) @ any wind >= 40 mph (18 m/s) Ib (Turbine Thrust Load: 2500 Ib (11.1 kN) @ any wind >= 40 mph (18 m/s)); Distance, Blade Tip to Tower Centerline 60 inches (1.52 m) inches (Distance, Blade Tip to 60 inches (1.52 m)
Tower Centerline); Turbine Center of Mass 5.1 inches (0.13 m) forward (upwind) of tower center inches (Turbine Center of Mass: 5.1 inches (0.13 m) forward (upwind) of tower center and 16.5 inches (0.42 m)
above the tower top); Turbine Center of Mass 16.5 inches (0.42 m)
above the tower top inches (Turbine Center of Mass: 5.1 inches (0.13 m) forward (upwind) of tower center and 16.5 inches (0.42 m)
above the tower top); Blade first flap frequency 5.5 – 6.0 Hz Hz (Blade first flap frequency is 5.5 – 6.0 Hz); Stall Regulation Speed 150 RPM RPM (Stall Regulation Speed: 150 RPM); Maximum Rotor Speed 170 RPM RPM (Maximum Rotor Speed: 170 RPM); Turbine Output Wiring 3-phase AC (Turbine Output Wiring: The output is a 3-phase AC.)
products:Most people choose to purchase a Tower Wiring Kit along with the Tower Kit.https://www.bergey.com/wp-content/uploads/excel-10-self-supporting-lattice-tower-installation-manual-2.pdf
products:hardware provided in the Tail Assembly Hardware Kithttps://www.bergey.com/wp-content/uploads/excel-10-self-supporting-lattice-tower-installation-manual-2.pdf
39120000 Electrical equipment and components and supplies
Standard: IEEE1547 (complies with the
requirements of IEEE1547); Input Voltage Maximum (3 Phase Input) 480 VAC VAC (Input Voltage Maximum (3 Phase Input) 480 VAC); Input Start Voltage Minimum 270 VAC VAC (Input Start Voltage Minimum 270 VAC); Input Operating Voltage Range 270 to 480 VAC VAC (Input Operating Voltage Range 270 to 480 VAC); Input Frequency Maximum 47 Hz Hz (Input Frequency Maximum 47 Hz); Input Current Maximum 34 Amps Amps (Input Current Maximum 34 Amps); Continuous Output Power Maximum 22600 W W (Model PSIII-240 PSIII-208
Continuous Output Power Maximum 22600 W 18800 W); Continuous Output Power Maximum 18800 W W (Model PSIII-240 PSIII-208
Continuous Output Power Maximum 22600 W 18800 W); Continuous Output Power Tolerance ±10% % (Continuous Output Power Tolerance ±10%); Output Voltage Nominal (Single Phase) Line-Line 240 VAC VAC (Output Voltage Nominal (Single Phase) Line-Line 240 VAC 208 VAC); Output Voltage Nominal (Single Phase) Line-Line 208 VAC VAC (Output Voltage Nominal (Single Phase) Line-Line 240 VAC 208 VAC); Output Voltage Nominal (Single Phase) Line-Neutral 120 VAC VAC (Output Voltage Nominal (Single Phase) Line-Neutral 120 VAC); Operating Voltage Range Line-Neutral 106-132 VAC VAC (Operating Voltage Range Line-Neutral 106-132 VAC); Continuous Output Current Maximum 90 Amps Amps (Continuous Output Current Maximum 90 Amps); Operating Frequency Nominal 60 Hz Hz (Operating Frequency Nominal 60 Hz); Operating Frequency Range 59.3 to 60.5 Hz Hz (Operating Frequency Range 59.3 to 60.5 Hz); Output Over-Current Protection Maximum 100 Amps Amps (Output Over-Current Protection Maximum 100 Amps); Dimensions 32.2”H ” (Dimensions 32.2”H x 24.3”W x 9” D); Dimensions 24.3”W ” (Dimensions 32.2”H x 24.3”W x 9” D); Dimensions 9” D ” (Dimensions 32.2”H x 24.3”W x 9” D); Enclosure NEMA Type 1 (Enclosure NEMA Type 1)
products:Powersync III
Grid-Intertie Inverterhttps://www.bergey.com/wp-content/uploads/Excel-15S-Owners-Manual_August-2018_Rev-0.pdf
43222903 Telecommunication tower or support (commodity)
Tower Height 60 ft. ft. (Tower Height 60 ft. 80 ft. 100 ft. 120 ft. 140 ft. 160 ft.); Tower Height 80 ft. ft. (Tower Height 60 ft. 80 ft. 100 ft. 120 ft. 140 ft. 160 ft.); Tower Height 100 ft. ft. (Tower Height 60 ft. 80 ft. 100 ft. 120 ft. 140 ft. 160 ft.); Tower Height 120 ft. ft. (Tower Height 60 ft. 80 ft. 100 ft. 120 ft. 140 ft. 160 ft.); Tower Height 140 ft. ft. (Tower Height 60 ft. 80 ft. 100 ft. 120 ft. 140 ft. 160 ft.); Tower Height 160 ft. ft. (Tower Height 60 ft. 80 ft. 100 ft. 120 ft. 140 ft. 160 ft.)
products:Table 3: Lift Weight and Lift Point for SSL Towershttps://www.bergey.com/wp-content/uploads/excel-10-self-supporting-lattice-tower-installation-manual-2.pdf
products:the optional BWC Tower
Wiring Kit is purchased with the towerhttps://www.bergey.com/wp-content/uploads/excel-10-self-supporting-lattice-tower-installation-manual-2.pdf
Certificate: AWEA 9.1-2009 (Certifications
AWEA 9.1-2009); AWEA Rated Power 15.6 kW at 11m/s (24.5 mph) kW (AWEA Rated Power
15.6 kW at 11m/s (24.5 mph)); AWEA Rated Sound Level 48.5 dB(A) dB(A) (AWEA Rated Sound Level
48.5 dB(A)); AWEA Rated Annual Energy 29,800 kWh at 5 m/s (11 mph) kWh (AWEA Rated Annual Energy
29,800 kWh at 5 m/s (11 mph)); Start-up Wind Speed 4.5 m/s (10 mph) m/s (Start-up Wind Speed
4.5 m/s (10 mph)); Cut-in Wind Speed 2.5 m/s (5 mph) m/s (Cut-in Wind Speed
2.5 m/s (5 mph)); Nominal Peak Power 25 kW @14 m/s (31 mph)* kW (Nominal Peak Power
25 kW @14 m/s (31 mph)*); Cut-Out Wind Speed None (Cut-Out Wind Speed
None); Max Design Wind Speed 60 m/s (134 mph) m/s (Max Design Wind Speed
60 m/s (134 mph)); Type 3 Blade Upward, Horizontal Axis (Type
3 Blade Upward, Horizontal Axis); Rotor Diameter 31.5 ft (9.6m) ft (Rotor Diameter
31.5 ft (9.6m)); Max Rotor Speed 150 RPM RPM (Max Rotor Speed
150 RPM); Blade Pitch Control None, Fixed Pitch (Blade Pitch Control
None, Fixed Pitch); Over Speed Protection Blade Stall, with dump load (Over Speed Protection
Blade Stall, with dump load); Gearbox None, Direct Drive (Gearbox
None, Direct Drive); Temperature Range -40 to +60 Deg. C (-40 to +140 Deg. F) Deg. C (Temperature Range
-40 to +60 Deg. C (-40 to +140 Deg. F)); Generator Permanent Magnet Alternator, Direct Drive (Generator
Permanent Magnet Alternator, Direct Drive); Output Form 3 Phase AC, Variable Frequency 240 VAC, 1Ø, 60 Hz with Powersync III inverter (230 VAC, 1Ø, 50 HZ available soon) (Output Form
3 Phase AC, Variable Frequency 240 VAC, 1Ø, 60 Hz with Powersync III inverter (230 VAC, 1Ø, 50 HZ available soon))
products:EXCEL-S SYSTEMS ONE-LINE ELECTRICAL DIAGRAMhttps://www.bergey.com/wp-content/uploads/excel-10-self-supporting-lattice-tower-installation-manual-2.pdf
products:For special assistance please contact the Service Department at Bergey Windpower
Companyhttps://www.bergey.com/wp-content/uploads/excel-10-self-supporting-lattice-tower-installation-manual-2.pdf
Tower height 20 foot foot (Tower height is increased in 20 foot
increments by adding new sections to the base of the tower structure.); tower 60 FT FT (BASE OF 60 FT TOWER); tower 80 FT FT (BASE OF 80 FT TOWER); tower 100 FT FT (BASE OF 100 FT TOWER); tower 120 FT FT (BASE OF 120 FT TOWER); tower 140 FT FT (BASE OF 140 FT TOWER); tower 160 FT FT (BASE OF 160 FT TOWER)
products:The SSL Tower Kit is comprised of material from Rohn and BWC.https://www.bergey.com/wp-content/uploads/excel-10-self-supporting-lattice-tower-installation-manual-2.pdf
products:For problems or
symptoms not found in the following listing please contact the Service Department at
Bergey Windpower Co.https://www.bergey.com/wp-content/uploads/Excel-15S-Owners-Manual_August-2018_Rev-0.pdf
site_on_owner_website (medium, website, other page)Anhueser-Busch Brewery
Report wrong
Groups
a group of one (only this company): no group knownurn:matchory:group:01m772v38jfd8tsqdfetpqvdds - via self, consolidating
From the same website
Every subject the run of the same website produced: named on the same website, not a corporate group; a relation between them, if any, is under Relations.